Richmond 5v40-7 Water Heater Specs |verified| Jun 2026
: Standard anode rod installed to protect the tank from mineral-based decay. Certifications
The Richmond 5V40-7 water heater comes with several features that make it an attractive option for homeowners:
Whether you are auditing your home's current HVAC hardware, attempting a DIY repair, or looking for an exact structural replacement, understanding the baseline operational engineering of this unit is critical. Core Specifications Overview richmond 5v40-7 water heater specs
Typically utilizes screw-in type heating elements. These are standard and easily replaceable. If the unit is installed in an area with hard water, the lower element may eventually require replacement due to sediment buildup (scale).
| Specification | Detail | |---------------|--------| | Energy Factor (EF) | 0.59 (pre-2015 standard) / UEF: 0.62 (Uniform Energy Factor) | | First Hour Rating (FHR) | 67 gallons | | Recovery Rate | 38.8 gallons per hour (at 90°F rise) | | Standby Heat Loss | ~4-5% per hour (typical for standard tank) | : Standard anode rod installed to protect the
The Richmond 5V40-7 has been known to experience some common issues as it ages. Understanding these problems and their solutions can save homeowners time and money.
ClearancesFor safe operation and future maintenance, a minimum of 2 inches of clearance from combustible materials is generally required, though 12 inches of front access is recommended for servicing the pilot light and gas control valve. Warranty and Reliability These are standard and easily replaceable
The tank features a porcelain-lined interior, offering excellent corrosion resistance to prolong the life of the water heater.
Ensure proper clearances are maintained per local codes (usually around 6 inches for sides/back, 12 inches for front).
(at $1.00/therm): Approximately $280–$330 per year, depending on usage.