Be cautious when downloading PDFs from unverified sites. Many search results for "Supertester Ice 680 R manual pdf" may lead to ad-filled pages or fake downloads. Always prioritize known manual libraries or manufacturer archives. If you cannot find the original manual, the closely related or Amprobe 680 R manuals may share 90% of the same functions and can serve as a temporary reference.
The Definitive Guide to the Supertester ICE 680 R Go to product viewer dialog for this item. Manual PDF: Features, Usage, and Maintenance The Supertester ICE 680 R Go to product viewer dialog for this item.
: Resistance circuits are protected by a 160 mA glass cartridge fuse to prevent damage from accidental voltage application. Special Functions
To measure a specific value, you must insert your test leads into the correct combination of sockets.
Several versions of the manual are available in PDF format, often categorized by the "Serie" (Series) of the device: VI Serie (6th Series): supertester ice 680 r manual pdf
Whether you need to replace the obsolete 3V battery, repair a broken switch, or simply learn how to measure a 22,000 μF capacitor via the mains connection, the original manual is your essential companion. With this guide and the correct PDF, you can keep your ICE 680 R running for another 50 years.
: DC ranges from 100 mV to 1000 V ; AC ranges from 10 V to 750 V (expandable to 2500 V with optional probes). Current : DC ranges from 50 A to 5 A ; AC ranges from 250 A to 2.5 A . Resistance : Measures from 0 to 10 M Ωcap omega using multipliers. It includes a specific "Low Ωcap omega " test for values as low as 0.1 Ωcap omega
Leo looked at the countdown now glowing on the 680 R’s screen: .
The manual details how to read the multiple arcs on the dial. The top scale is typically for resistance (Ohms), while the lower arcs cover DC and AC ranges. Always ensure you are looking at the correct arc corresponding to the socket your probe is plugged into. 2. Zeroing the Needle (Mechanical & Electrical) Be cautious when downloading PDFs from unverified sites
requires batteries for resistance testing. Open the rear case carefully to replace them, ensuring polarity is correct.
The Internet Archive hosts user-uploaded scans of rare manuals.
Before diving into the manual, it is essential to understand why the ICE 680 R remains so highly regarded. The company, ICE (Industria Costruzioni Elettromeccaniche), built these instruments to last for decades. The is a high-precision analog multimeter capable of performing a wide range of measurements.
Leave a comment below describing the specific schematic or page you need (e.g., "Capacitance leakage test procedure"), and we will post that exact excerpt from our reference manual. If you cannot find the original manual, the
| Problem | Likely Cause (from manual) | Solution | | :--- | :--- | :--- | | | Mechanical blockage or debris in coil gap. | Gently tap the case. Do not blow compressed air into the movement. | | No reading on Ohms | Dead 1.5V or 9V battery. | Replace both batteries, even if one looks new. | | Inaccurate DC Voltage | Worn probe leads (high resistance). | Test leads with a DMM; replace if above 0.5 Ohms. | | Needle bounces slowly | Overload damage (shorted internal diode). | Requires calibrated service center (rare parts). | | AC reading drifts | External magnetic field (speaker or transformer nearby). | Move meter 12 inches away from power sources. |
The BEHA-Amprobe (formerly ICE) Supertester 680 R is a legendary analog multimeter known for its rugged build and high internal resistance (typically 20 kΩ/V), making it ideal for vintage electronics and industrial troubleshooting. However, finding an official, readable PDF manual for this discontinued model can be frustrating.
prevents accidental overloads and ensures precise readings. The technical core of the instrument relies on a highly sensitive galvanometer. Specifications & Range Ωcap omega AC Sensitivity Ωcap omega DC Voltage Ranges 100mV, 2V, 10V, 50V, 200V, 500V, 1000V AC Voltage Ranges 10V, 50V, 250V, 750V (Extendable to 2500V) DC Current Ranges A, 5mA, 50mA, 500mA, 5A AC Current Ranges A, 2.5mA, 25mA, 250mA, 2.5A, 10A Ohmic Ranges (up to 10 M Ωcap omega Special Tests Continuity (buzzer), Diode/LED, Low Ωcap omega , Decibels, Battery Test Internal Power 9V Battery (Type 6F22) Core Hardware Features