Manual: Convo Inverter Cvf G3
Connect the 3-phase power supply to L1, L2, L3 . Motor Terminals: Connect the motor leads to U, V, W .
Causes: Input voltage is below minimum operational specifications or main contactor failed.
Connect incoming AC power lines to terminals (for 3-phase units) or R and T (for single-phase units). Convo Inverter Cvf G3 Manual
: After turning off the power, wait at least 10 minutes before touching the radiator or internal components to prevent burns or electric shock from residual charges.
Are you controlling it via the ? I can provide the exact parameter sequence for your setup. Connect the 3-phase power supply to L1, L2, L3
| Code | Fault | Possible Cause | Solution | |------|-------|----------------|----------| | OC1 | Over-current during acceleration | Short circuit, fast acceleration | Increase accel time (F0.10), check motor insulation | | OC2 | Over-current during deceleration | Fast deceleration | Increase decel time (F0.11), add braking resistor | | OC3 | Over-current at constant speed | Load shock, motor stall | Check load, increase drive capacity | | OU1 | Over-voltage during deceleration | Regenerative energy | Extend decel time, add braking unit | | OU2 | Over-voltage during acceleration | Input voltage too high | Check supply voltage | | LU | Under-voltage | Power dip, missing phase | Check input power | | OH | Overheat | Fan failure, ambient too high | Clean heatsink, replace fan | | OL1 | Motor overload | Motor overcurrent | Check load, adjust F1.00-F1.03 | | OL2 | Drive overload | Excessive current | Reduce load or upsize drive | | CE | Communication error | Wiring, baud mismatch | Check RS485 wiring, match baud rate |
| Parameter | Specification | | :--- | :--- | | | Three-phase, 380V (±15%), 50/60Hz | | Output Voltage | 0V to Input Voltage | | Output Frequency | 0Hz to 500Hz | | Control Method | V/F Control | | Overload Capacity | 150% for 60 seconds (G3) | | Operating Temp. | -10°C to +40°C | | Humidity | 90% RH or less (non-condensing) | Connect incoming AC power lines to terminals (for
For industrial liquid-pumping systems or constant-pressure ventilation networks, the CVF-G3 features an internal proportional-integral-derivative (PID) tracking system.
Check motor insulation, wiring leads, and output phases for short circuits. Reduce mechanical load torque or check for a locked rotor.
Includes Sensorless Vector Control (SVC) and SVPWM for high speed and torque accuracy. Protection: