Invt Che100-0r7g-s2 Manual [portable] -
If the motor turns backward, power down the unit, wait for the capacitors to discharge, and swap any two phases of the output wires ( and V ).
The manual dedicates an entire chapter (Chapter 7) to fault codes. Here are the most common errors for the CHE100-0R7G-S2:
The is an indispensable resource for any technician or engineer working with this drive. It provides all the necessary information, from basic safety and installation guidelines to advanced parameter configuration, communication setup, and troubleshooting.
The model number contains critical information about its capabilities: 1-Phase 220V ±15% Output Power: 0.75kW (approx. 1 HP) Frequency Range: 0Hz to 400Hz
: Voltage class and phase. "S2" indicates a Single-Phase 220V AC input ( 2. Technical Specifications Specification Details Input Voltage Single-Phase 220V AC, 50Hz/60Hz (Range: 187V–264V) Output Voltage Three-Phase 0V to Input Voltage, 0Hz–400Hz Rated Output Current 4.5 Amperes (A) Applicable Motor 0.75 kW (1 HP) 3-phase induction motor Control Mode Sensorless Vector Control (SVC), V/F Control Overload Capacity 150% of rated current for 60 seconds; 180% for 10 seconds Cooling Method Forced air cooling with built-in DC fan Enclosure Rating IP20 (Must be mounted in a clean, dust-free enclosure) 3. Installation and Environmental Requirements invt che100-0r7g-s2 manual
To ensure optimum airflow and longevity, the drive must be mounted vertically on a flat, flame-retardant surface (such as a steel backplate inside an electrical enclosure).
When a protective function is triggered, the VFD shuts down output and displays an error code on the LED interface. Common Fault Codes :
: Rated for 0.75kW with an output current of 4.5A.
However, like any sophisticated electronic device, its full potential is only unlocked through proper configuration. This is where the becomes indispensable. Whether you are an electrician, maintenance engineer, or a DIY automation enthusiast, this article serves as a comprehensive companion to the official manual, covering installation, parameter settings, fault codes, and where to download the latest PDF. If the motor turns backward, power down the
Whether you are setting up the inverter for the first time, optimizing motor control for a demanding application, or diagnosing a fault, the manual is your definitive guide. Users should always keep it in an easily accessible place and refer to it whenever necessary to ensure safe operation, protect the equipment, and fully utilize the capabilities of the INVT CHE100-0R7G-S2.
Decelerates the motor to a stop. It also resets the VFD after an error trip has been cleared. Essential Parameter Programming
Analog Input 1. Accepts a 0–10V DC signal or a 4–20mA current loop to control motor frequency remotely.
The manual begins with a crucial safety section, explicitly categorizing risks as or CAUTION . Warnings indicate a potentially hazardous situation that could lead to death or serious injury, while cautions indicate a situation that could lead to minor or moderate injury. It provides all the necessary information, from basic
Increase P0.12 (Decel Time); check line voltage; install dynamic braking resistor if required. Overcurrent during Accel/Decel
Based on the INVT CHE100 series manual (often titled CHE100 Series High-performance Vector Control Inverter ), here are the key features for that specific model ():
A significant portion of the manual is dedicated to troubleshooting. It lists common fault codes, their possible causes, and recommended actions.